Stationary Automatic Sampler

LYSAM-SN is an outdoor stationary automatic water sampler that uses a vacuum water sampling method. It is operated using a color touch panel, and sampled water is stored in a refrigerator. In addition, water sampling history and alarm history can be retrieved using a USB memory stick.Optional features include auto-drain water sampling and high-head water sampling up to 30m.*The control unit window is optional.

Main function

1. Timing of water collection and method of distributing the sample into bottles Automatic water sampling by programming
2. Setting the amount of water to be collected at one time
3. Starting the water sampling program by external input signal
4. Controlling the progress of the water sampling program using external input signals
5. Contact output for alarm status, operation status, etc. of this device (JS specification)
6. Save 5 types of water sampling programs
7. Water sampling history and alarm history record
8. SDI-12 communication (optional)
9. Refrigerate and store collected water samples

specification

Water sampling target

General sewage, rainwater, industrial wastewater, sludge, rivers, lakes, etc.

Main unit

Main materialSUS304 (standard), SUS316 (optional)
sizeW800×H1750×D750 (excluding protrusions)
displayTFT color touch panel
Ambient temperature0 to 50°C
Ambient humidity25 to 95% RH (no condensation)

function

Water sampling methodDiaphragm pump type (vacuum water sampling)
Water collection speed0.9m/s or more with horizontal pull of 3m and lifting height of 6.2m
Water sampling accuracy (reproducibility)Within ±2%
Water intake headV1: 8.5m V2: 9.5m (single suction)
V3: 20m V4: 30m (double suction)
V5: 18m (hybrid)
Measuring part500mL chamber and variable volume top
(1L and 2L are optional)
Sample bottle2L x 24 bottles, 30L x 1 bottle
Water sampling hose(sampling line)Soft PVC black braided hose
ID9.5 x OD16
connector with strainer
temperature displayThermistor type water temperature sensor (optional)
Data loggerRecords water sampling time, mode, bottle number, temperature inside the chamber, water sampling results, analog instantaneous values, etc., and collects data via USB memory
inputTouch panel programming
timerDelay or real-time timer
Water sampling modeTime proportional water sampling, flow proportional water sampling (analog), irregular interval water sampling
Water sampling controlExternal water sampling control (analog, contact, water temperature (optional))
Water sampling control by day of the week
Irregular interval water sampling
Water sampling intervalTime proportional: 1 to 9999 (unit: min)
Flow proportional: 1 to 99999 (unit: m3)
Number of divided water samples2 to 999 times
Distribution methodComposite water sampling, single water sampling, multi-sample water sampling, multi-bottle water sampling, day-step water sampling, auto-drain water sampling (optional)
Cycle SettingsWater collection cycle and retry count settings
Temperature recording functionLogging of water temperature at each sampling point (optional)

Analog Signal Input

DC4 to 20mA (standard 1 point, maximum 2 points)
flow rate, water quality, etc.

Abnormality signal input

No-voltage contact signal

power supply

AC100V 50/60Hz

Power consumption

Standard 550W, high head 800W
(rush current 50Hz 23A, 60Hz 22A)

Body mass

Approximately 300kg

Standard accessories

Water collection bottle2L x 24 bottles (stored inside the bottle case)
Water sampling hose10m (with connector and strainer) 1 set
Composite Bottle30L x 1 bottle
rubber seal1 pair

option

  • Sample bottles (2L x 24 bottles, 4L x 12 bottles, 8L x 4 bottles, 10L x 2 bottles, 30L x 1 bottle, etc.)
  • Chamber and top (1L, 2L)
  • Water sampling start level detector
  • SDI-12 communication capability
  • High lift specifications (20m/30m)
  • Anti-siphon function
  • Polyurethane coating
  • AC200V specification
  • Strainer (SUS304)
  • Water Temperature Sensor
  • Auto-drain water collection function
  • Intermediate tank lifting device
  • Hose cleaning function
  • Salt damage prevention specifications
  • Casters (with stoppers)
  • Control room window
  • Analog signal (2 points)

Installation conditions

Since the LYSAM series uses a vacuum water sampling method, the sampling point must be installed at a lower position than the chamber. Install the water sampling hose so that it does not slope backward from the chamber to the sampling point.

Disposal

Please contact us for a fee. *Refrigerant recovery is also available.

Recycled Design

The LYSAM series aims to create environmentally friendly products, and is mindful of reducing, reusing, and recycling.*Please note that specifications may be changed without notice for improvement purposes.*The shape and performance of the product may change depending on the installation environment, construction conditions, etc.