DEPTH VELOCITY FLOW MONITOR

The DVFM was developed as a flow meter for open channels such as sewers. It calculates the cross-sectional area of ​​the flow from the water level signal sent from a sensor installed in the measurement channel, and the average flow velocity from the flow velocity signal, and then multiplies these values ​​to convert them into flow rate.The water level, flow velocity and flow rate are displayed on the LCD and output as analog signals and integrated pulse signals (optical MOSFET).In addition, limit alarms can be set by programming and output as relay contact signals.

Main function

1. Calculate flow rate from water level and flow velocity values
2. Display of water level, flow velocity and flow rate values
3. Display of flow rate total
4. Limit alarm status display
5. Analog output of water level, flow velocity and flow rate
6. Flow rate totalizing pulse output
7. Limit alarm output
8. Watchdog Output9. Programming (Setup)
10. Water level calibration and output test using software

specification

Measurement target

General sewage, rainwater, industrial wastewater, agricultural water, river water, etc.

Main unit

Main materialMade of resin
sizeW345×H421×D202 (cable lock and latch not included)
displayLCD (20 full-width rows x 4 columns)
Ambient temperature0 to 50°C (however, avoid direct sunlight)
Ambient humidity25 to 95% RH (no condensation)
attachmentRear mounting type (recommended for installation inside the panel)

sensor

Main materialMade of urethane resin
sizeW34.5×H32×L203
Water level measurement partSUS316 diaphragm type
range3.5m, 10m
pressure resistance3.5m range: 14m, 10m range: 42m
Water level accuracy3.5m range: ±2% (relative to actual water level) ±3mm10m range: ±2% (relative to actual water level) ±10mm
Flow velocity measurement partUltrasound Doppler
range0 to ±5 m/s, bidirectional measurement possible
Measurement ModeForward, reverse, unidirectional, bidirectional
Flow velocity accuracy±2% FS
Dedicated cableStandard 30m
Ambient temperature0 to 50°C
attachmentFixed to the bottom of the waterway using dedicated mounting brackets (standard)

Flow Measurement Accuracy

±5 to 10% RD (Accuracy can be improved by correcting flow rate)

Analog Output

scoreStandard 3 points (select from water level, flow velocity, and flow rate)
kindsDC4~20mA (maximum load resistance 1000Ω)

Flow Pulse Output

Optical MOSFET (withstand voltage 200V, load current 150mA)

Contact Output

Contact CapacityRelay contact (DC24V 1A, AC110V 0.5A)
kindsLimit alarm (2 points): Select from water level, flow velocity, and flow rateWatchdog pulse: Output when malfunction occurs due to some cause

program

Display contentWater level, flow velocity, flow rate value or limit alarm status
set upParameters and various outputs
ParametersCircular pipe, rectangular culvert, canal with haunch*Special canal shapes require separate ROM creation.

power supply

AC100V 50/60Hz, power consumption 20W

Body mass

Approximately 7kg

Measurement principle

The water level is detected as water pressure by a diaphragm pressure transducer at the bottom of the sensor. A pressure-receiving element whose resistance changes with pressure changes is embedded inside the transducer, and the change in resistance is amplified as a change in voltage and output to the converter. The sensor cable has a built-in air tube, and the transducer is compensated for atmospheric pressure.Flow velocity is obtained by detecting the Doppler effect of ultrasonic waves emitted from the front of the sensor into the water. Ultrasonic waves emitted into the water are reflected by air bubbles and impurities in the water. These objects move with the flow according to the flow velocity distribution in the waterway, and the average flow velocity can be obtained by analyzing the received signal accompanied by the Doppler effect. Flow rate (Q) can be obtained by multiplying the cross-sectional area of ​​the flow (A), calculated geometrically from the water level, by the average flow velocity value (V). (Q=V・A) Measurement values ​​can be output as analog signals, and an integrated flow rate pulse can also be output.

Installing the sensor

The sensor is generally fixed to the bottom of the measurement channel using a dedicated mounting bracket.

Related Equipment

JIS compliant products (planned: 

JIS B 7557 Drainage flowmeters - for trade or certification ), portable electromagnetic flow meters, portable surface velocity/PBF flow meters, rectifiers (baffles, blocks, etc.), flow monitoring systems (packet communications, cloud, regional IP networks, telemetry, etc.), IoT compatible